The Five-Minute Checklist When a Robot Stops
Before deciding a robot is faulty, run through these in order, most likely cause first. If the robot runs normally afterward, you have your answer. If it stops again in open water with a clean filter and a straight cable, ask a pool expert.
- Cable: pull the robot in and look at the cable. If it is coiled like an old phone cord, unplug it from the power supply, lay it straight on the deck and let the twist run out.
- Filter: open it. If it is packed, empty and rinse it, including fine panels, which clog before they look dirty.
- Obstacle: note where it stopped. Against a drain dome, behind a ladder or in a step corner points to the feature, not the robot.
- Depth: if it stopped high on a step or ledge, the water there is too shallow for it.
- Air: submerge the robot, tilt it until the bubbles stop, and restart.
Stuck, Stalled or Simply Finished?
Not every motionless robot is stuck. When the cycle time is up the robot stops, often wherever it happens to be. Check the power supply before anything else, because a finished cycle and a stoppage look the same from the deck.
A true stoppage has a pattern, and the pattern is useful. The same step corner every time is a geometry problem, often cured by moving the power supply so the robot approaches from another side. Random places with a coiled cable mean twist. Low in the deep end with a heavy robot means a full filter.
The Escape, which we also sell, sits where the Cayman does on this question, with a shorter 40 ft cable: sound tracks and scanning, no swivel.
Habits That Prevent Most Stoppages
- Empty and rinse the filter at least weekly, and after every cycle in leaf season. Do it before the robot tells you it needs it.
- With the Cayman, straighten the cable on the deck before each run, since it has no swivel to do that for you.
- Put only as much cable in the water as the pool needs, with the power supply roughly central. Spare cable wraps around ladders.
- Let the air out every time: lower the robot in, rock it until the bubbles stop, then start the cycle.